The highest quality
“TFC RO MEMBRANE”
MCM introduces a full line of high-quality household in-line water filter for POU&POE drinking water market, delivering consistent quality products and performance. When incorporating MCM TFC RO Membrane into your POU&POE system, we are sure you and your customers will receive the highest level of water purity and trouble free performance.
Full Automatic Membrane Production Consistent and Superior Quality Control
100% Inspection Complete
production line inspection and test
in – factory quality control system
statistical process control system
Quality Assurance
– 100% Inspection before shipment
– Full automatic inspection and test
– On-line quality control system Features
Features
– Dry type Membrane sheet applied for longer shelf life (12month)
– Membrane sheet from top-tier manufacturer
– FDA certified thin film composite membranes
– NSF performance test passed
The membranes are tested and certified by NSF International against NSF/ANSI Standard 58.
These elements have been tested for the reduction of Arsenic, Barium, Cadmium,
Chromium (Hexavalent), Chromium (Trivalent), Copper, Fluoride, Lead,
Radium 226/228, Selenium, Turbidity, and TDS.
Looking for better RO Membranes?
“MCM HAS THE ANSWER!”
Operating Limits
– Membrane Type | Polyamide Thin-Film Composite |
– Max. Operating Temperature | 113℉ (45℃) |
– Max. Operating Pressure | 125psi (8.6bar) |
– Max. Feed Flow Rate | 2.0 gpm (7.6lpm) |
– pH Range, Continuous Operation | 3.0 ~ 10 |
– Max. Feed Silt Density Index | < 5 |
– Free Chlorine Tolerance | < 0.1ppm |
Model name | Permeate Flow Rate (GPD) | Applied Pressure Psig (bar) | Stabilized Salt Rejection (%) | Minimum Salt Rejection (%) | Remarks |
TW30-1812-50 | 50 | 60 (4.1) | 98 | 96 | Dry type elements |
TW30-1812-75 | 75 | 60 (4.1) | 98 | 96 | Dry type elements |
TW30-1812-80 | 80 | 60 (4.1) | 98 | 96 | Dry type elements |
TW30-1812-100 | 100 | 80 (5.5) | 98 | 96 | Dry type elements |
TW30-1812-150 | 150 | 80 (5.5) | 98 | 96 | Dry type elements |
1. Permeate flow rate and salt rejection based on the following test conditions : 250ppm (NaCl) softened tap water, 77℉(25℃), 15% recovery, pH 7.5 and the specified applied pressure.
2. Permeate flows for individual elements may vary ±20%.
3. For the purpose of improvement, specifications may be updated periodically.
4. The membranes are tested and certified by NSF International against NSF/ANSI Standard 58.